Cirque Royal
Bruxelles
Venue
Building
Hall
Stage
Machinery
Lighting
Audiovisual
Venue
VENUE TYPE:
Theatre
USE:
Showing: Yes
POSSIBILITY OF HOUSERENTING:
Yes
OUTSTANDING SHOWS DUDING 1999:
Carmen
PROGRAMME PLANNING MONTHS:
January
February
March
April
May
June
September
October
November
December
Building
ADDRESS:
Rue de l'Enseignement
1000 Bruxelles
Region: Bruxelles-Capitale
Province: Bruxelles-Capitale
Telephone: 32 (0) 2 218 20 15
Fax: 32 (0) 2 250 00 81
PROPERTY:
Ville de Bruxelles
1000 Bruxelles
Belgique
OPERATION:
A.S.B.L. Cirque Royal
Rue de l'Enseignement
1000 Bruxelles
Belgique
TOWN' CONNECTIONS:
Aircraft
Train
Bus
PUBLIC TRANSPORTS TO THE BUILDING:
Bus Tube
BUILDING' SITE:
Center
DOOR' ACCESS:
Trailer
STAFF:
Manager or director: Annie VALENTINI.
Telephone: 32 (0) 218 20 15
EARLY TICKET SALE:
Box office: Yes
MINIBAR OPEN ONLY DURING PERFORMANCES:
Yes
HANDICAPPED ACCESS:
Yes
HANDICAPPED TOILET:
Yes
Hall
HALL DIMENSIONS (CM):
Wide (max): 2600
Depth: 2300
Height (max): 1800
TOTAL CAPACITY:
2948
Fix seats: 1228
Movil seats: 1720
HALL CONFIGURATION:
Stall : Steps section
Number of floors : 3
AUDIENCE-SCENE RELATIONSHIP:
Fix
3 sides
DRESSING ROOMS:
Single (number of places): 4
Groups (number of places): 110
NUMBER OF REHEARSAL HALLS:
1
Stage
STAGE DIMMENSIONS (IN CM):
WIDE:
Fore-stage : 1500
Fix proscenium arch : 1280
Stage right : 150
Stage left : 100
Orchestra pit : 1300
DEPTH:
Fore-stage : 468
From the proscenium arch : 1525
Stage rigth : 1400
Stage left : 1400
Orchestra pit : 1300
HEIGHT:
Proscenium opening : 800
Stage level to grid : 1170
Orchestra pit : 140
LOAD ACCESS:
Direct access to stage level : Yes
Distance from the load door to stage (m) : 2
Minimum measures of load door to the stage:
Wide (cm): 295
Height (cm): 365
RAKED STAGE:
0 %
STAGE FLOOR:
Fix
Machinery
GRID NUMBERS:
2
FLY FACILITIES NUMBER:
Manual bars : 15
Motorized bars : 26
TECHNICAL ROOF:
Yes
Wide : 1500
Depth : 3600
Approachable roof : Yes
OTHER FIXED SUPPORT ON THE STAGE ROOF:
Yes
Total bars number : 41
HALL SUPPORTS:
Parallel fly galleries to the stage : 1
Fix brackets for spotlights : Yes
STAGE CLOTH:
Safety curtain : Yes
Front drop : 1
Back drop : 2
Side masking (legs) : 6
Top masking (border) : 4
STAGE MANAGER DESK:
Fix
Lighting
POWER SUPPLY (VOLT.) :
380
Total power : 692 Amp
TOTAL NUMBER OF DIMMER CIRCUITS IN THE AUDITORIUM:
122
TOTAL NUMBER OF DIMMER CIRCUITS IN THE STAGE:
70
DIMMERS:
192 ADB ATN 5000W
CONTROL DESK:
ADB S20
CONTROL DESK POSITION:
Into the auditorium
SIGNAL:
Digital
AMX 113
Connection points number : 1
SPOTLIGHT TOTAL NUMBER:
86
Audiovisual
SOUND POWER SUPPLY (VOLT.) :
380
Total power : 63 Amp
SOUND CONTROL DESK POSITION:
Into the auditorium
INTERCOM SYSTEM:
Fix (connection points number) : 15